Shelf Life Testing
Our shelf life testing protocol may be customized for each type of food product you submit.
The shelf life is the recommended maximum time for which products or fresh produce can be stored after processing or harvesting before reaching a level of unacceptable degradation in quality.
The stability testing protocol may be customized for each type of food group or processed product submitted. Appropriate tests to determine the identity, wholesomeness and quality of the product will be outlined prior to the initiation of the stability study.
Testing is performed to measure the bacterial integrity of a finished product. Demonstrating the absence of pathogenic bacteria in the product is the safest way of avoiding consumer cases regarding food borne illness. The finished report is an excellent sales tool as it indicates that the product is shelf stable and free of pathogenic bacteria for the specified period of time.
A projected shelf life period should include a reasonable time for production, distribution, sale and consumption. The stability study should also establish product safety for an acceptable time beyond the actual recommended expiration date. The laboratory will assist you in setting up a shelf life study to meet your specific needs. Most importantly, if a problem is identified, the study is halted. Any issue is immediately communicated so it can be addressed prior to repeating the study. Our process lends itself to be an iterative part of your product development.
Kappa Labs offers microbiological, chemical and physical types of shelf life testing. Microbiological testing, the most common method in the food industry, measures the product’s resistance to microbial growth. Test results show how well the product safety is retained by comparing the overall bacterial growth during the testing period to established acceptable limits. Chemical testing measures the degree to which the product retains it chemical integrity and potency, within specified limits. Physical testing evaluates how well the product’s original physical properties, including appearance, palatability, odor, and wholesomeness are retained.
Accelerated Shelf Life Study:
The FDA has established the guidelines for Accelerated Stability studies primarily for pharmaceutical products. Since a different set of guidelines for food products does not exist, the pharmaceutical standards also apply to the Accelerated Shelf Life studies in food products. A three month testing period at elevated temperature 35 degrees Centigrade is equivalent to one year of product shelf life. During the testing period, the microbiological profile of the product is monitored. Tests in the microbiological profile include, Total Aerobic Plate Count, Coliform Count, Fecal Coliform Count, E. coli, Staphylococcus Aureus, and Mold and Yeast tests. If the product is stable there should not be an increase in microbial content as the product is incubated. Salmonella and Listeria are tested along with all of the tests listed at the Initial time point, one month, two month and three month time points. Two years of Accelerated Shelf Life study would require six months of incubation with additional testing time points.
Room Temperature Shelf Life Study:
Ambient temperature studies are carried out at 25 degrees Centigrade and are conducted in real time. The testing is carried out in the same manner for each time point. Products which are not able to be heated or where mold and yeast may be a problem, such as baked goods, would be tested under these conditions.
Refrigerated Shelf Life Study:
An initial sample is tested for the following ????? Microbiological Series when the samples are received. After being tested, the sample is returned to the chemistry laboratory and the pH is measured. The remaining three samples are placed under refrigeration at 33 Degrees Fahrenheit until the time they are to be tested. The time points for the testing in a refrigerated study are determined by the nature of the product. The following tests will be performed according to the AOAC ???? methods cited below.
Analyses Performed:
Total Aerobic Count (Aerobic Plate Count): FDA Bacteriological Analytical Manual (BAM), 8th Edition, Chapter 3, 1998.
Coliform Count & E.coli: AOAC, 17th Edition Chapter 17, Section 966.23 – 966.24. FDA Bacteriological Analytical Manual (BAM), 8th Edition, Chapter 4, 1998.
Staphylococcus Aureus: AOAC, 17th Edition Chapter 17, Section 975.55 & 987.09. FDA Bacteriological Analytical Manual (BAM), 8th Edition, Chapter 12, 1998.
Total Molds and Yeast (Aerobic Plate Count) FDA Bacteriological Analytical Manual (BAM), 8th Edition, Chapter 18, 1998.
*PCR Salmonella spp and Cultural Confirmation: SOP 1.1, AOAC – RI 051303
*PCR Listeria spp. and Cultural Confirmation: SOP 2.2, 2.2, AOAC – RI 071304
*PCR Listeria monocytogenes and Cultural Confirmation: SOP 2.1, 2.2, AOAC – RI 061302
*Initial Time Point
Time Points to be Examined (example)
A projected Shelf Life should include a reasonable time for production, Distribution, Sale and Consumption. Also, the Shelf Life should be established beyond the actual expiry date to insure that an out of date product is safe beyond the expiry date marked. A projected expiry date of fourteen (14) days should have a final time point at 18 to 21 days. The data will then provide a margin of documented Product Safety. Time Points would be Initial, Day 7, Day 14 and Day 21. Each product will be evaluated prior to running the study to determine the time points to be tested.
Coliforms – Coliform bacteria are indications of general sanitation status of the product.
E. coli – E. coli is a human fecal marker and should not be present. May represent a pathogen.
Staph. aureus – Staphylococcus aureus is a common cause of food poisoning derived from product handling.
Mold /Yeast – Can be spoilage organisms and can produce aflatoxins. Some individuals have allergic reactions to both mold and yeast.
Upon the completion of the study a report is issued containing the four sets of test results indicating the testing time points. The results will declare the stability of the product and the report will contain the following statement:
Based upon the Microbiological results of the sample listed above and insofar as the analyses performed were able to assay for the presence or absence of specific pathogens, the product represented by the sample analyzed would appear to be wholesome and fit for human consumption for a projected shelf life of (time indicated)
Samples needed: 5 individual containers
Turn Around Time: Accelerated three months (1 year) (refrigerated – real time)
Cost Shelf Life Testing: $550.00 – Please send payment with samples
Extra Timepoints: $95 per timepoint
*Requires five (5) finished product samples to be submitted per product per study.
*Contact Laboratory for Chain of Custody to be submitted with samples.
Kappa Laboratories has been Inspected and previously Recognized by the U.S. Department of Agriculture (USDA Microbiology-#0093, Chemistry-#1282); ISO 17025 Certified Listeria species, Listeria monocytogenes, Salmonella species; Registered with the U.S. Food and Drug Administration (FDA-#1039390) and is an FDA Accepted Laboratory for Import Testing. Kappa Laboratories is currently a Contract Laboratory to the U.S. Centers for Disease Control (CDC), Atlanta, Georgia; Vessel Sanitation Program. Contract Laboratory, U.S. Coast Guard for Alaskan Vessel Discharge Program. ISO/IEC 17025 Accredited: Salmonella spp., Listeria spp. And Listeria monocytogenes.
http://www.cdc.gov/nceh/vsp/cruiselines/lab_listing.htm
To Get Started
Send an e-mail to the Kappa Labartories (info@kappalabs.com) or use the contact form below. Be sure to include with the following details.
- Description of the sample to be analyzed.
- Description of matrix to be analyzed.
- Determination of methods to be employed.
- Number of samples and number of analytes to be determined.